Decimal point Alarm indicator Transport A maximum of three devices may be connected together. Start/Stop Infusion Special Functions / Function key First press F to access the special functions of the pump (= Select / Enter key). In the event of power failure, the pump automatically switches to battery power.ĥ Clear data Alarm silence for 2 min. Mains Connection Connection for the power supply. 4 (1) (2) Multi-Function Connector (MFC) Connection for staff call, ambulance (12 V) and interface. Taking care to observe waste disposal regulations (see also page 21). Remove screw (1), press in the green tab (2) and slide compartment door down. Battery Compartment Disconnect the pump from the patient while changing the battery. Syringe Adapter Locking Lever To move the drive unit manually, push the locking lever up until it clicks. Syringe Holder Locks the syringe in place. Instructions for Use and Syringe Table Slide-out short instructions for Use and a syringe table are attached underneath the pump. Operation To access functions, first press the F button Display Shows all important information at a glance: rate, syringe type, power source, infusing symbol and alarm symbols (see "Alarms on page 11). 3Ĥ Overview Handle Always use the handle when carrying. For further details please refer to the Instructions for Use. The medical specialist must decide on suitability for application on the basis of the warranted properties and the technical data. IEC/EN a transportbale infusion syringe pump for administrating fluids in nutritional therapy and infusion technique as well as for home care applications. HF surgical equipment, nuclear spin tomography units, mobile telephones etc.) maintain the recommended protective distances for these devices.ģ Perfusor compact S Contents Perfusor compact S / Overview Operation Special Functions Start-up and Trumpet Curves Alarms / Displays Battery Operation Compatible Syringes Technical Data Warranty / TSC / Service / Cleaning Ordering The Perfusor compact S is according to IEC/EN resp. If the equipment is operated in the vicinity of other equipment which may cause high levels of interference (e.g. Safety Standards Perfusor compact S satisfies all safety standards for medical electrical devices in compliance with IEC/EN and IEC/EN The EMC-limits (electro-magnetic compatibility) according to IEC/EN and IEC/EN are maintained. The international standard IEC/EN has to be taken into account. The user/operator is responsible for the system configuration if additional equipment is connected. Connected electrical equipment must comply with the relevant IEC/EN-pecifications (e.g. incompatible disposables may influence the technical specifications. Use only compatible combinations of equipment, accessories, working parts and disposables. Refer to respective manufacturer s information for possible incompatibilities of equipment resp. Where several infusion lines are connected on one single vascular access the possibility of their exerting a mutual influence vice-versa cannot be excluded. as caused by change of level) can affect the accuracy of the device. Other components Variations in pressure (e.g.
![braun perfusor compact user manual braun perfusor compact user manual](https://data2.manualslib.com/first-image/i34/168/16781/1678091/braun-perfusor-compact-plus.jpg)
If staff call is used we recommend to check the equipment once after connecting the pump. Do not use the device when service indicator is displayed permanently. Start infusion only if values are corresponding. Compare displayed value with entered value. Possible explosion hazard if used in presence of flammable anaesthetics. Observe national specifications and deviations. Installation in medically used rooms must comply with the appropriate regulations (e.g. Recommended change of disposables after 24 h (consider national hygiene regulations).
#Braun perfusor compact user manual free
Position the infusion line free of kinks. Select syringe/catheter suitable for use with the intended medical application.
![braun perfusor compact user manual braun perfusor compact user manual](https://www.medkitservice.com/media/catalog/product/cache/3/image/800x/9df78eab33525d08d6e5fb8d27136e95/p/e/perfusot-compactplus2.jpeg)
Interrupt the connection during syringe changes to prevent incorrect dose delivery. Connect to patient only after switching on the device. Also check the device for possible damage. Prior to use check audible and visual alarms during self test. Operation Ensure the unit is properly positioned and secured. Application only under regularly supervision by specially trained staff.
#Braun perfusor compact user manual software
1 Perfusor compact S Instructions for Use Software BEĢ Patient Safety Attention: Consult accompanying documents! Read Instructions for Use prior to use.